Meiji MT6530 Trinocular PCM Asbestos Microscope - NIOSH 7400, OSHA ID 160

Meiji Techno
SKU:
MT6530
$58,942.79
$66,227.85
(You save $7,285.06 )
  • Trinocular head, 360° rotatable
  • KHW10x/20mm eyepieces
  • Walton & Beckett reticle
  • Plan Semi Apochromat 4x, 10 & Positive Phase 40x Objectives
  • 6V 30W Halogen illumination with variable control
  • LIMITED LIFETIME WARRANTY
Current Stock:
Adding to cart… The item has been added

The MT6530 Newly Designed PCM (Phase Contrast) Compound Microscopes for Asbestos fiber counting applications. Meiji Techno manufactures these microscopes pursuant to NIOSH 7400 and OSHA ID 160 Reference methods. Each model comes with centering telescope, 1mm stage micrometer, GIF 546nm filters and built-in Koehler illuminator as standard equipment. The specifications table below shows the features of each model.

Asbestos Fiber Counting by Phase Contrast Microscopy

Methodology for PCM Analysis: NIOSH 7400 & OSHA ID160
Phase contrast microscopy is the method that is primarily used for estimating asbestos concentrations of airborne fibers. This method is quick and can be performed on-site for a rapid determination of concentrations of asbestos fibers in the air. Phase contrast microscopy does not positively differentiate between asbestos and other fibers. Positive identification of asbestos fiber must be performed using PLM (Polarized Light Microscopy) or Electron Microscopy (Method 7402)

Required Microscope Equipment
Positive phase contrast microscope with 10X Brightfield and 40X Phase objectives, GIF (Green Interference Filter), Walton & Beckett reticle Type-22G and a stage micrometer with 0.01mm divisions.

Required Test Slide
The HSE/NPL Mark II Phase Shift Test Slide checks or standardizes the visual detection limits of the phase contrast microscope. The HSE/NPL Test Slide consists of a conventional glass microscope slide with seven sets of parallel line pairs of decreasing widths. The microscope must clearly resolve line pairs 1 thru 3. Line pairs 4 and 5 must be at least partially visible. Line pairs 6 and 7 must be invisible. A microscope which fails to meet these requirements is either too low or too high in resolution and cannot be used for asbestos detection.

WARRANTY
Lifetime warranty.

Product Specifications

Viewing Bodies Trinocular Siedentopf head, 30° inclination, graduated diopter on left eyetube (23.2mm I.D. eyetube) with interpupillary adjustments of 53mm to 75mm, Inverted image.
Eyepiece KHW10X compensating eyepiece, Field No. 20, tube O.D. 23.2mm
KHW10X Focusing eyepiece with Walton & Beckett reticle, Field No 20 (Eyetube O.D. 23.2mm)
Objectives Infinity Corrected Plan Semi Apochromat 4x & 10x
Infinity Corrected Plan Semi Apochromat positive Phase Contrast objective 40x
Stage Ceramic coated flat-top stage, 170mm x 140mm, with 80mm x 52mm X-Y movement and right hand drop-down coaxial controls
Condenser Abbe condenser N.A. 1.25 with iris diaphragm with centerable phase annuli for 20x & 40x phase objectives, dovetail mount
Focusing Coaxial coarse and fine focus adjustment with graduation, reading 2 microns per division with tension adjustment and safety auto focus stop.
Illumination 6V 30W Halogen Koehler illumination with Integrated Automatic Voltage Sensing Power Supply
Includes Focusing Centering Telescope, 23.2mm O.D.
Green interference filter 546mm, 44.0mm diameter, unmounted
Blue clear filter, 44.0mm diameter, unmounted
Stage Micrometer-1mm divided into 100 units, 0.01mm(each división= 0.01mm)
Warranty LIMITED LIFETIME WARRANTY
Certification CE and ISO 9001

Shipping

Calculate shipping costs at cart or checkout. Our representatives are also happy to assist you by requesting a quote.

For further information, please refer to our Shipping Policy.

Weight:
28.00 LBS
Width:
16.00 (in)
Height:
14.00 (in)
Depth:
21.00 (in)

Returns

If you are dissatisfied with your purchase, let us help you with a refund or exchange. Exclusions may apply.

For full details, view our Returns Policy.